MIL-M-45122(Ord)
Req. Para.
Test Method
Minor AQL - 2.5 per cent
5.3.2.3
Improper packing (container over-
Visual
size; indequate or excessive cushioning
material; etc.)
5.4.1.1
Visual
Non-adherence to the requirement
of prescribed shipping container
specification
Manual - visual
5.3.1.5.2.4
Immobilized items and interior
packages
TABLE III - CLASSIFICATION OF DEFECTS
(Use Inspection Level L7, and Sampling Plan Table
IV-A of Standard MIL-STD-105)
Test Method
Major AQL - 2.5 per cent
Req. Para. Q.A. Para.
5.3. 1.5.1.2 4.3.13
visual
Heat Seal (Level A)
5. 3.1.5.1.2 4.3.13
visual
Quick Leak (Level A)
4.2.3 Inspection Equipment.- The test methods and procedures outlined
in 4.3 shall be used as standards for determining the adequacy of the con-
tractor's inspection equipment and methods utilized for inspecting the
characteristics in Table I. Unless otherwise specified in the contract, the
contractor shall provide and maintain gages and other measuring and testing
devices considered necessary for inspection of supplies for conformance to
contracted requirements. The Government reserves the right to certify all
such equipment and to use this equipment for Government verification inspec-
tion.
4.3 Test methods and procedures.
4.3.1 Orientation.- To determine compliance with the requirements herein,
the telescope mount shall be positioned on a suitable device, special testing,
in compliance with the requirements of 3.5.
4.3.2 Vibration.- The mount shall be positioned on a vibrating device in
accordance with 3.4 and vibrated at the frequency, amplitude, and time period
designated in 3.4.
4.3.3 Elevation level vial. - The elevation level vial bubble shall be
located in compliance with 3.5.2 when mounted as specified in 3.5.
4.3.4 Cross level vial.- The cross level vial bubble shall be located in
compliance with 3.5.2 when mounted as specified in 3.5.