MIL-DTL-48555B
4.3.2.1
Quadrant.
Drawing number
13005101
Next higher
assembly
Conformance
Requirement
None
Classification
Examination or test
criteria
paragraph
Inspection
method reference
Critical
None defined
Major
101
Presence of Plate,
100%
3.3
Visual
Identification, 13010954
102
Completeness of assembly
100%
3.3
Visual/tactile
103
Storage temperature
3 units per lot 1/
3.4.1
4.4.1
104
Operating temperature
100%
3.4.2
4.4.2
105
Shock
100%
3.4.3
4.4.3
106
Vibration "B"
100%
3.4.5
4.4.5
107
Sealing
100%
3.5
4.5
108
Purging
100%
3.6
4.6
109
Cleanliness
100%
3.7
4.7
110
Elevation counter
100%
3.8.1
4.8.1
excursion range
111
Correction counter
100%
3.8.2
4.8.2
excursion range
112
Elevation accuracy
100%
3.8.3
4.8.3
113
Backlash
100%
3.8.4
4.8.4
114
Correction counter setting
100%
3.8.5
4.8.5
effect on elevation counter
115
Correction counter setting
100%
3.8.6
4.8.6
effect on elevation level
bubble
116
Knob torque
100%
3.9
4.9
117
Counter numerals
100%
3.10
4.10
118
Level vial illumination
100%
3.11
4.11
119
Counter illumination
100%
3.12
4.12
120
Interchangeability
100%
3.13
4.13
Minor
201
Workmanship
VL-II
3.14
4.14
NOTES:
1/ Lot shall be accepted if there are 0 failures, and rejected if there are 1 or more failures.
4.3.3 Conformance inspection to be performed. The conformance inspection shall
be performed in accordance with Table III and 4.3.2.1.
4.3.4 Conformance rejection. If any item of the sample fails to comply with any of
the conformance requirements, the lot shall be rejected.